Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/6535
Title: Technology advances in diabetes pregnancy: right technology, right person, right time
Authors: McLean, Anna 
Maple-Brown, Louise
Murphy, Helen R
Issue Date: 2024
Source: McLean A, Maple-Brown L, Murphy HR. Technology advances in diabetes pregnancy: right technology, right person, right time. Diabetologia. 2024 Oct;67(10):2103-2113. doi: 10.1007/s00125-024-06216-2. Epub 2024 Jul 5. PMID: 38967667; PMCID: PMC11447080.
Journal Title: Diabetologia
Journal: Diabetologia
Abstract: This review outlines some of the extraordinary recent advances in diabetes technology, which are transforming the management of type 1 diabetes before, during and after pregnancy. It highlights recent improvements associated with use of continuous glucose monitoring (CGM) but acknowledges that neither CGM nor insulin pump therapy are adequate for achieving the pregnancy glucose targets. Furthermore, even hybrid closed-loop (HCL) systems that are clinically effective outside of pregnancy may not confer additional benefits throughout pregnancy. To date, there is only one HCL system, the CamAPS FX, with a strong evidence base for use during pregnancy, suggesting that the pregnancy benefits are HCL system specific. This is in stark contrast to HCL system use outside of pregnancy, where benefits are HCL category specific. The CamAPS FX HCL system has a rapidly adaptive algorithm and lower glucose targets with benefits across all maternal glucose categories, meaning that it is applicable for all women with type 1 diabetes, before and during pregnancy. For women of reproductive years living with type 2 diabetes, the relative merits of using non-insulin pharmacotherapies vs diabetes technology (dipeptidyl peptidase-4 inhibitors, glucagon-like peptide-1 receptor agonists and sodium-glucose cotransporter 2 inhibitors) are unknown. Despite the urgent unmet need and potential benefits, studies of pharmacotherapy and technology use are extremely limited in pregnant women with type 2 diabetes.
Description: Cairns & Hinterland Hospital and Health Service (CHHHS) affiliated author: Anna McLean
DOI: 10.1007/s00125-024-06216-2
Keywords: Automated insulin delivery;Closed-Loop;Continuous glucose monitoring;Diabetes technology;Neonatal;Obstetric;Pregnancy;Review;Type 1 Diabetes;Type 2 Diabetes
Type: Article
Appears in Sites:Cairns & Hinterland HHS Publications

Show full item record

Page view(s)

26
checked on Dec 25, 2024

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.